DC-DRIVES:
Features:
* Adjustable soft start and soft
end
* Adjustable current limit
* I R compensation
* Minimum & Maximum Armature voltage latch
* Phase reversal/Phase fail tripping with indication
* Field
fail tripping with indication
* Potential free enable
* On and external fault relay o/p's present
* One link changeover from
Armature to
Tacho feedback and vice versa.
* Output for RPM/Percentage meter available.
MODEL-9612-01
This DC-Drive ranges from 0.25H.P. to 1.0H.P. It has a
input of single phase 240V AC; 50Hz. We can have stable,
regulated output from 0 to 180V DC through a potential
free ON/OFF contact and a 4K7 pot. It can give stable
output from180V AC to 270V AC as input. It has all the
features of any modern type dc-drive like current limit;
soft start; IR Compensation; maximum and minimum o/p latch
and fuse protection.
MODEL-09Q11
This DC-Drive ranges from 0.5 to 3.0H.P. It has all the
features of model 9612-011 in addition it has a solid
state field failure protection, which can be used for
series wound, laminated yoke and shunt type motors, where
as for permanent magnet motors it can be by-passed. Single
card version. Size is 225X235X90mm.
MODEL-07Q11
This is a presision type trouble free tough drive used
for heavy-duty hours. Has all the features of model-09Q11
plus it has isolated voltage and current feedbacks, and
its two cards and a choke for extra protection is mounted
on a backallite of approximate size 320X425mm, with a
height of 100mm.
MODEL-10Q1X
This has all the features of model-07Q11 leaving choke
and is in the form of double- deckker, lower part is power
section and upper is control.
It is different from model-07Q11 as it does not have a
field failure protection but can be provided optionally
if demanded, also it can operate on single as well as
two phase supply but this has to be mentioned at the time
of ordering.
MODEL-11Q42
It is a four-quadrant drive used for applications where
instant stopping is required.
It finds application in lifts, CNC and SPM. It takes input
from a 2-phase supply through a centre tap transformer
and gives a output from -180V DC to +180V DC, through
a pot.
MODEL-12Q13
It is a single quadrant; three phase dc-drive used for
higher ratings ie 5.0H.P. to 60.0H.P. It has features
like field failure protection; single phasing / phase
fail protection; current limit; soft start; soft end;
IR Compensation; over temperature trip; minimum and maximum
output latch & 6 pulse synchronising.ln this drive
output can be set from 0 to 380/440V DC as desired.